Workman MD-4 External Extra Large S/RF Meter
|
MD-4 External Meter |
 |
|
The Case Dimensions
6-9/16"W x 3-9/16"H x 2"D
Bottom Feet 3/8" |
|
MD-4 Illuminated Meter Movement In Low Light |
|

|
|
Meter Face Dimensions
3-7/8"W x 1-15/16"H |
The Workman MD-4 external meter is designed to plug into
euro style radios that have a 2.5 mm external meter jack on the rear panel
such as the Super Star 4900B. Some of the later President radios also have
this external meter jack. The meter works like the internal meter for both
TX output & RX signal strength. The adjustment on the front is to
calibrate the meter to the radio. It can also be used to sensitize the
meter to indicate very small signal strength changes for radio checks or
used to desensitize the meter in fox hunts or tracking down carriers once
in close proximity of the source.
The MD-4 has a meter input cable terminated with a 2.5mm
plug and meter lamp wires which connect to 13.8 volts. The blue
illumination blends in very well with automotive lighting. It can also be
wired to the vehicle dimmer switch on mobile installations. In base
station installations the lamp leads can be wired internal to the radio
13.8 volt source.
|