2002
Model DeltaForce - Modification Update
-
Make
sure DeltaForce is turned off and disconnected from power
source!!
-
Take
off speaker-side cabinet.
-
Find
the CPU Reset Board located near the rear panel of the radio
(see diagram below).
-
On
the CPU Reset Board are 4 jumper positions (CON1 - CON4). Each
jumper position provides a different frequency range and
configuration. From the list below, select the desired frequency
range and configuration, and move the jumper shunt to the
corresponding CON.
CON1
:10 Meter Only
(28.000 - 29.699 MHz)
CON2
:10 Meter &
Expanded Mode
-
At
turn on, the radio defaults to 10 Meter mode.
-
For
Expanded mode, press FUNC and then press CALL for 3 seconds.
-
To
return to 10 Meter mode, repeat above steps.
-
For
information on Expanded mode operation, see CON3
CON3
: Expanded Mode
Only (25.165 - 29.699 MHz)
-
ln
Expanded mode, the frequency range is divided into 10 bands of
40 channels each
-
Bands
are shown on LCD display by letters (A through J) - Band E is
regular 40 channel CB. To switch bands, press the CALL button
(do not hold down for 3 seconds).
-
ln
Expanded mode, either the frequency or channel can be displayed
on the LCD. To switch between frequency display and channel
display, press the FUNC button and then press the CALL button
(do not hold down for 3 seconds).
-
0n
the channel display, the small number (0 - 9) to the right of
the Band letter is the 1 kHz frequency display. Example: If the
frequency is 27.405, then the channel display will indicate 40
E5. "40" being the channel, "E" being the
Band, and "5" being the 1 kHz position of 27.405.
-
ln
Expanded mode, the RPT and SHIFT functions do not operate
CON4
: 40 Channel CB
Only (26.965 - 27.405 MHz)
|